7,000 Gal Fuel Trucks
The AEG 7,000-Gallon Jet A Refueler pairs an International HV607 SBA 6x4 chassis with a 304 stainless steel tank built to DOT 406 and NFPA 385/407 standards, giving FBOs and ramp operators a dependable, code-compliant refueler for general and commercial aviation fueling. Its 300/100 GPM fueling system, dual overwing and underwing hose configuration, and full suite of safety interlocks make it a versatile mid-capacity solution, with a 600 GPM upgrade path available for higher-throughput operations.
Key Features
• International HV607 SBA 6x4 chassis with automatic transmission and hot-shift PTO, speed limited to 25 MPH for ramp safety
• 7,000-gallon, 304 stainless steel #4 finish tank built to DOT 406 and NFPA 385 compliance
• Scully Intellicheck 3 overfill protection with primary and secondary high-level shutoff and ultrasonic level sensing tied to TCS3000
• 300/100 GPM fueling system with one underwing and two overwing nozzles, each on independent electric rewind reels
• Dual TCS meters with TCS3000 electronic register heads and Epson electric printers for accurate, documented transactions
• Upgradeable to 600 GPM with a scissor lift fueling platform and 4" boom or JAC riser hose system
• Stainless-steel piping, brackets, and sense/drain tubing throughout, plus electric emergency shutoffs and reverse alarm
Technical Specs
Chassis: International HV607 SBA 6x4, automatic transmission w/ hot-shift PTO, speed limited to 25 MPH
Tank: 7,000-gallon, 304 stainless steel #4 finish; DOT 406 & NFPA 385 compliant
Safety Systems: Primary/secondary high-level shutoff, Scully Intellicheck 3, ultrasonic level sensor (TCS3000), pneumatic vent and internal valve
Fueling System: 300/100 GPM; 2" x 50' MxM API hose w/ underwing nozzle (45-PSI HECV); (2) 1-1/4" x 50' MxM API hoses w/ OPW overwing nozzles
Metering: (2) TCS meters w/ TCS3000 electronic register heads and Epson electric printers
600 GPM Upgrade: Scissor lift fueling platform; 4" boom or JAC riser hose system; (2) 2.5" x 11' MxM API hoses; (2) underwing nozzles (45-PSI HECV)
Optional: 20-gal recovery tank, additive injection, thermal compensation, cellular modem, engine bay fire suppression
Also Included: Stainless-steel piping/brackets/tubing, multiplex or PLC control system, electric emergency shutoffs, (2) 20-lb BC fire extinguishers, reverse alarm, NFPA 407 decals, O&M manual